1. stress testing
method
:Static seal: 1.5 times the working pressure for 30 minutes, pressure drop ≤5%.
Dynamic seal: step up pressure test, observe the leakage point.
2. Leak diagnostics
Common leak types
:interface leakage
The sealing surface is uneven, and the groove needs to be reprocessed.osmotic leakage
Material is incompatible with the medium, replace the sealing material.
3. Regular maintenance
suggestion
:Check seal compression set every 500 hours (refer to ASTM D395).
Under high temperature conditions, replace the elastomer seals every 6 months.